DAY ZONES
Day Zones operate when the panel is fully disarmed, i.e. when Area 1, Area 2
and Monitor are all off. When alarmed, these zones will activate the assigned
outputs instantly.
The outputs mapped to the Day Zone will turn on while the zone is unsealed.
Turn P64E 2E on, to limit Day Zone alarms to 2 seconds.
PROGRAMMING SEQUENCE:
P53E [Zone No]E toggles the options ON and OFF
P53E [Zone No]E OFF: The zone is not a Day zone
P53E [Zone No]E ON: The zone is a Day zone
P53E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
all OFF: No Day zones
NOTES:
• RELATED OPTIONS:
P63E 5E–8E Day zone output mapping
P64E 2E 2 sec Day Mode alarm
• TYPICAL USES:
Instant alert when a delivery door is
opened.
Doorway alert for a shop. Turn ON option
P63E 7E for keypad sonalert when a
Day zone alarms.
24hr ZONES
24hr Zones operate at all times regardless of the mode of panel operation, i.e.
Armed, Disarmed or Monitor. When alarmed, these zones will activate
assigned outputs immediately. To reset those alarms a valid user code must
be entered.
Selecting a zone as 24hr will override any other zone type setting such as
Instant, Delayed or Handover.
PROGRAMMING SEQUENCE:
P52E [Zone No]E toggles the options ON and OFF
P52E [Zone No]E OFF: The zone is not a 24hr zone
P52E [Zone No]E ON: The zone is a 24hr zone
P52E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
all OFF: No 24hr zones
NOTES:
• The Tamper input is always a 24hr zone
• For silent 24hr zones, simply deselect the
zone/s from options P54E–P57E (Reset,
Strobe, Sonalert & Siren)
• To change a 24hr zone to any other
zone type, the zone must also be re-
assigned to an AREA (P45E or P46E).
24hr zones are independent of Area
operation. All other zone types must be
assigned to at least one Area to
become active.
MONITOR ZONES
Monitor zones allow you to Arm selected zones while others are ignored.
Typically used for perimeter zones such as windows and doors while you are at
home. Example: Upstairs zones are Disarmed while downstairs zones are
Armed in Monitor mode.
PROGRAMMING SEQUENCE:
P51E [Zone No]E toggles the options ON and OFF
P51E [Zone No]E OFF: The zone is not a Monitor zone
P51E [Zone No]E ON: The zone is a Monitor zone
P51E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
all OFF: No Monitor zones
NOTES:
• RELATED OPTIONS:
P63E Monitor Mode output mapping
P64E 1E 2 second Monitor Mode alarm
P64E 3E Monitor zones have Entry
Delay2