35
PROGRAMMING
E-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUAL
24HR ZONE FIRE SIREN SOUND
This option changes the siren sound when a 24hr zone is triggered.
PROGRAMMING SEQUENCE:
P68E 6E toggles the option ON and OFF
P68E 6E OFF: Fire siren sound disabled
P68E 6E ON: Fire siren sound enabled
P68E 6E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
OFF: No 24hr Fire siren sound
NOTES:
• The keypad key sequence for FIRE (3 E)
always outputs the FIRE siren sound
4th BUTTON RADIO KEY FOR AUX1
E-Tech 4 Button Radio Key only – this option changes P68E 3E and 4E to work
with the 4th Button of a 4 Button Radio Key instead of the PANIC button.
PROGRAMMING SEQUENCE:
P68E 7E toggles the option ON and OFF
P68E 7E OFF: 4th button Radio Key for AUX1 disabled
P68E 7E ON: 4th button Radio Key for AUX1 enabled
P68E 7E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
OFF: 4th button for AUX1 disabled
NOTES:
• RELATED OPTIONS:
P68E 3E & 4E Radio Key Panic to AUX1
QUIET CHIRPS ON ARM/DISARM
This quietens the siren chirps that are made whenever keyswitch or radio key
Arming or Disarming is used.
(Arm/Disarm Chirps must be enabled at P64E 4E).
PROGRAMMING SEQUENCE:
P68E 8E toggles the option ON and OFF
P68E 8E OFF: Quiet Chirps disabled
P68E 8E ON: Quiet Chirps enabled
P68E 8E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
OFF: Quiet Chirps disabled
NOTES:
• RELATED OPTIONS:
P64E 4E Arm/Disarm Chirps
RADIO KEY ARMING, UNSEALED ZONE WARNING
Setting this option ON allows a 2 second SIREN warning if there is an unsealed
zone in an Area Armed by a Radio Key.
PROGRAMMING SEQUENCE:
P68E 5E toggles the option ON and OFF
P68E 5E OFF: Radio Key arming, siren warning disabled
P68E 5E ON: Radio Key arming, siren warning enabled
P68E 5E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
OFF: Radio Key siren warning disabled
NOTES:
•